RAMSES ESP

Flows

All flow cards of the app, with examples.

Ventilation unit

When…

CardTokensNotes
The fan mode changedMode, Changed byOn every mode change. Changed by is homey, remote or unit.
The fan mode changed to [mode]Only for a particular mode.
A boost startedMinutes, Started byAlso when someone starts the boost on the remote.
The unit reported a fault
The fault of the unit is gone
The filter needs replacingWhen the unit turns on its filter alarm.

And…

Card
The fan mode is / isn't [mode]
The unit has / has no fault

Then…

CardNotes
Set the fan mode to [mode]Low, medium, high, auto, away or off (what your brand supports).
Run on high for [minutes] minutesBoost of 1–255 minutes; the unit then falls back.
Set the bypass to [auto / open / closed]Only for units with a bypass.
Set [parameter] to [value]For heat recovery units with parameters. Start typing to search for a parameter.
Reset the filter counterAfter replacing the filter.
Ask the unit for its statusMakes the unit report all its values right away.

Remote and sensor

When…

CardTokens
The [Low / Medium / High / Auto / Away / Off / Boost] button was pressedBoost minutes
Any button was pressedButton, Boost minutes

The card Any button was pressed gives in Button the word low, medium, high, auto, away, off or boost.

Virtual CO₂ sensor

Then…

Card
Report [ppm] ppm CO₂
Report [%] % humidity
Ask the unit for [%] % ventilation

See Virtual CO₂ sensor for the explanation.

Gateway

These cards are for those who want to go deeper. You'll need some knowledge of the protocol.

When…

CardNotes
A packet was receivedFires for every packet on the bus. Can be busy!
A [code] packet was received from or to [address]Filter on message code and address. Address * matches any device.
A new device was found on the busTokens Address and Role (fan, remote, sensor, gateway, unknown).
The gateway went offline
The gateway came online

The packet triggers have these tokens:

TokenExample
VerbI, RQ, RP or W
From29:173894
To29:233244
Code22F1
Payload000304
Frame I --- 29:173894 29:233244 --:------ 22F1 003 000304
Signal (RSSI)45

And…

Card
The gateway is / isn't online

Then…

CardNotes
Send frame [frame]A complete RAMSES II frame, exactly as it appears on the bus.
Send [verb] [code] with payload [payload] to [address]Sent from the gateway's own address.

With raw frames you can send anything, including to your neighbours' units. Only send commands to your own devices and test with RQ (request) before using W (write).

Examples

Shower: boost on high humidity

When the humidity of Bathroom sensor changed
And the humidity is greater than 75 %
And Ventilation — the fan mode isn't High
Then Ventilation — Run on high for 30 minutes

Everybody out: away mode

When the last person left home
Then Ventilation — Set the fan mode to Away

When the first person came home
Then Ventilation — Set the fan mode to Auto

Cooking: boost when the cooker hood turns on

When the power of Cooker hood plug became greater than 50 W
Then Ventilation — Run on high for 20 minutes

Notification for a dirty filter

When Ventilation — The filter needs replacing
Then send a push notification: The ventilation filter needs replacing.

And after replacing it, with a button or a voice command:

Then Ventilation — Reset the filter counter

Remote as a scene button

When Living room remote — The High button was pressed
Then set the living room lights to 100 %

The unit still responds to the button as usual; Homey only listens in.

Knowing who changed the mode

When Ventilation — The fan mode changed
And Changed by is remote
Then log: Someone set the ventilation to [Mode].

Warning for an offline gateway

When Ramses Gateway — The gateway went offline
Then send a push notification: The ramses_esp is offline.

Any CO₂ sensor in your home drives the unit

See Virtual CO₂ sensor.

Edit on GitHub